Proving a problem before buying
A YC-S200 reading before and after a trial installation is the cheapest way to settle whether static is actually the cause of a defect.
Static Detection
Static detection products help identify charged areas, compare static levels before and after neutralization, and support product selection for industrial static control projects.

Technical Parameter
The catalog detection section includes YC-S200 Static Voltage Meter, YC-S416 Electrostatic Monitoring System and YC-J100 Static Detection Sensor products.
| Model | Type | Measuring range | Standard distance | Output | Power | Accuracy / notes |
|---|---|---|---|---|---|---|
| YC-S200 | Hand-held static voltage meter | ±30 kV | 25 mm | — | 9 V DC | HI ±0.1 kV, LO ±0.001 kV, IB 1 V; non-contact measurement |
| YC-J100 | Static detection sensor | ±30 kV | 25 mm | 0–3 V | DC 5 V, ≤0.4 W | 100 ms output delay; 0–50 °C, 35–85 % RH; ABS housing |
| YC-S408 | Electrostatic monitoring system | — | — | — | — | Online monitoring of process points with abnormal-value alarm |
| YC-S416 | Electrostatic monitoring system | — | — | — | — | Online monitoring of process points with abnormal-value alarm |
Product Features

A YC-S200 reading before and after a trial installation is the cheapest way to settle whether static is actually the cause of a defect.
YC-J100 sensors feed the YC-S408 and YC-S416 systems for permanent monitoring of key points, with an alarm when readings go outside limits.
Non-contact measurement at ±30 kV over a 25 mm standard distance, for verifying that an installed bar is doing its job.
Where a defect appears intermittently, measurement at several points along the line usually locates the charge source faster than trial and error.

A high-performance DC static neutralization bar for wide-web and high-speed converting lines that need stable ion balance and flexible installation distance.
View Series
A practical DC ionizing bar series for static elimination on converting, packaging and web handling equipment.
View Series
An AC ionizing bar series for static elimination in film, paper, label and packaging applications where reliable neutralization is required.
View SeriesWe select from the manufacturer's published range against your application — we are not a static systems engineering house, and we would rather match the right component than sell you a study. The more of the following you can tell us, the closer the first recommendation will be.